Micro Multi Function Surgical Instrument Power Tools (System 8200)

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ -1

Description



Specification:
Electric HandpieceBJ8200 
Electric:Yes
Multifunctional: Yes
Weight (with battery): ≤1000 Grams
Speed:0-15000 rpm 
Power source:Battery
Sterilizable:Autoclavable
Battery:BJ8001
Technology: Ni-Mh 
Insert/detachment method:The telescopic
The blocking mechanism: Yes
Autoclavable Aseptic Transfer Kit:Yes
Run time with battery:30-40 min
Sagittal saw attachment:BJ8201
Oscillations (osc/min) 0-15000
Operation(V) voltage 7.2
Sterilization135°C
Noise(db) ≤45
Bone drill attachment:BJ8202
Speed(r.p.m) 0-1100
Torque(Nm)0.9
Operation(V) voltage7.2
Sterilization135°C
Noise(db) ≤40
Canulate drill attachment:BJ8203
Speed(r.p.m) 0-460
Torque(Nm)1
Operation(V) voltage7.2
Sterilization135°C
Noise(db) ≤40
Ao drill attachment:BJ8202SAO
Oscillations (osc/min) 0-1100
Operation(V) voltage 7.2
Sterilization135°C
Noise(db) ≤40
Reciprocating saw attachment:BJ8209
Speed(r.p.m) 0-15000
Torque(Nm)/
Operation(V) voltage7.2
Sterilization135°C
Noise(db) ≤45
K-wire drill attachment:BJ8213
Speed(r.p.m) 0-1100
Torque(Nm)1
Operation(V) voltage7.2
Sterilization135°C
Noise(db) ≤40
Notes:
1.Sterilize temperature ≤ 135 °C (Improved type ≤ 155 °C ),if the 
   temperature is over 135 ° C ,the motor will be damaged.
2.Normal bone drill can only hold drill bits less than 6mm,acetabulum 
   reaming drill with big torque,rpm is around 300,canulate drill is used 
   with nail or K wire ,rpm is around 600.
3.The battery need to be get out of the pwer tool after surgery. Otherwise 
   the small automatic discharge of the electric will make the life of the 
   battery short.
4.The battery cannot be sterilized ,it is not autoclavable.
5.The cranial bur must be washed right after the surgery by purger in 
   order to aviod the blood stick in the bur,then we should make it dry.
6.The battery space in the handpiece of the tool should not have any 
   water,after sterilization.
7.The cranial bur blade is made of medical stainless steel,in order to 
   avoid broken,so it is flexible and not very hard,it is easy to be attrite, 
   we suggest each blade only use for 1 surgery.


                                                       About us
          Established in 1993 and headquartered in Shanghai, Bojin, as an advanced orthopedic equipment
manufacturer and solutions provider, Bojin focuses on the development and marketing of orthopedic-purpose
motor products, X-ray imagescopes, treatment apparatus, and supporting surgical tools/parts. It has more than
one hundred types of orthopedic products under 8 series, which have received QC certification of 3C, ISO9001,
ISO13485, CE of the EU, and FDA Registry 3008787426. Its mission is to satisfy the needs of patients and
medical care with innovative high-tech products and therefore become a promoter of people's orthopedic health.
It has built a healthy sales and services network thanks to its 200 dedicated employees in the marketing
companies or teams in more than 4countries and regions across North America, Europe and Asia. Its products
are used in more than 60 countries and, in particular, in more than 20000 Chinese medical institutions 70%
of which are 3A-rated hospitals.



Product Tag:
Related categories:
Scroll to Top